Virginia, Co Cavan ‘A2’ Deep Retrofit Case Study

Together On Site

KORE case studies offer an inside look at how our EPS solutions perform in real-world applications. This deep retrofit was part of the 2017 Better Energy Communities Scheme, coordinated by KORE Retrofit and supported by the Sustainable Energy Authority of Ireland (SEAI).

Deep Retrofit Before
Insulation Deep Retrofit

Supported By

Fully Managed and Coordinated by

KORE Retrofit
SEAI

Case Study Details

Project Name: Deep Retrofit of a derelict house in Virginia, Co Cavan.

Products Used: KORE External Insulation, KORE Floor Insulation, KORE Warmroof, 6kW Daikin Heat Pump, uPVC Triple Glazed windows and external composite doors, Lunos Ventilation, 3kW Solr PV Array

Project Coordinator: KORE Retrofit Ltd.

KORE Project Manager:  Leighanne Fay

Achieving A2

With a total budget of €140,000 – or broken down to €80,000 towards the rebuild and €60,000 towards the energy efficiency works, KORE was able to renovate a derelict house from top to bottom. We achieved a final BER rating of A2 (29.65 kWh/m2/yr) and reduced carbon emissions to 6.88kgCO2/m2/yr. The final air tightness test results came in at a respectable 2.21m3/hr/m2 @50 Pa. SEAI provided partial funding at 50% for the energy efficiency works, reducing the cost to €110,000.

The “KORE” house represents a total expanded polystyrene (EPS) solution, showcasing all KORE has to offer under one roof. KORE EPS was utlised as floor insulationexternal wall insulation and as a warm roof solution, creating a low energy build with significantly reduced energy demand and carbon emissions – all while paying close attention to the airtightness layer around the roof and external walls, and minimising thermal bridging at the junctions.

The Energy Efficiency Problem

The derelict house pictured above, located in Killinkere on the outskirts of Virginia, Co. Cavan has sat in a dormant state since the Smith family moved house in 1985. Measuring in at 108.30m2 (1,162 square feet), this derelict cottage received a pre-BER rating of ‘G’, using 960.01 Kwh/m2/yr, putting it at the bottom of the building energy rating scale. Included in the 2017 Cavan Better Energy Communities Scheme funded in part by SEAI, KORE set out on a mission to re-build and retrofit, bringing it inline with today’s building regulations and energy standards.

Breaking down the details

Wall Insulation

The original 500mm stone walls were upgraded with 12.5mm plasterboard fixed with plaster dabs internally. 150mm of KORE External EPS70 Silver insulation and Kilsaren Ceresit External Wall Insulation render finish which achieved a U-value of 0.19W/m2K. The walls were also extended upwards and the window openings raised off the ground.

Floor Insulation

150mm KORE Floor EPS70 Silver, EPS perimeter strips and an 80mm screed with underfloor heating was installed over the original uninsulated concrete floor, achieving a U-value of 0.15W/m2K.

The KORE Warmroof Solution

To keep the attic space heated, KORE utilised an innovative warmroof solution with expanded polystyrene insulation to meet SEAI’s requirements for insulating an attic space. This warmroof system increased the home’s energy efficiency, decreased air leakage, reduced the risk of condensation, minimised the risk of thermal bridging and allowed for a heated indoor environment for both storage and services.

Internally, 165mm of KORE EPS70 Silver was fitted between 175mm rafters at 400mm c/c, and 12.5mm plasterboard was fitted to the sloped and flat ceiling

Externally, the roof was fitted with 18mm OSB board and taped at all joints. 50mm of KORE EPS100 White was placed on top of the OSB board, followed by sarking felt and timber battens and counter battens to increase airflow. Solar PV panels (16.64m2 PV array) were then placed in-line with the slate roof, generating 2,297 kWh/yr of electricity. The new roof construction, along with the KORE Warmroof solution achieved a U-value of 0.16W/m2K. This innovative EPS solution minimises the risk of perforations in the airtightness layer, and ensures continuity of the airtightness layer with the warm roof.

Heating & Ventilation Systems

KORE installed a 6kW Daikin ERLQ006CAV3 air-to-water heat pump to provide indoor space heating and underfloor heating. A Lunos V30/60 whole-house demand controlled ventilation system was also installed, along with occupancy and humidity sensors.

Windows and Lighting

KORE chose Camden uPVC triple-glazed windows with a U-value of 0.90W/m2K and 100 percent LED lighting throughout the entirety of the house. The windows were set out into the insulation layer which minimised thermal bridging. An electric car charging port was also added to the front of the house, diverting excess electricity generated by the solar PV panels when available. This can help further reduce the occupant’s carbon footprint.

For more information on being included in the Better Energy Communities Scheme please visit our retrofit solutions for further detail.

 

Leighanne Fay, Retrofit Sales & Project Manager

Leighanne has worked with KORE Retrofit since 2017, developing her skills in grant administration, finance, project management and sales. Leighanne is responsible for the One Stop Shop grant scheme, and the Vacant Refurbishment grant scheme. You can reach Leighanne by email or by phone at +353 87 146 9289

 
Previous
Previous

Ballyjamesduff, Co. Cavan ‘A3’ Deep Retrofit Case Study

Next
Next

Drumcrow, Co Cavan ‘A1’ Deep Retrofit Case Study